 (R)
ISO212P
FPO
Low Cost, Two-Port Isolated, 1500Vrms ISOLATION AMPLIFIER
FEATURES
q 12-BIT ACCURACY q 2.5mA (typ) QUIESCENT CURRENT q LOW PROFILE (LESS THAN 0.5" HIGH) q SMALL FOOTPRINT q EXTERNAL POWER CAPABILITY (8V at 5mA) q "MASTER/SLAVES" SYNCHRONIZATION CAPABILITY q INPUT OFFSET ADJUSTMENT q LOW POWER (53mW) q SINGLE 10V TO 15V SUPPLY OPERATION
APPLICATIONS
q INDUSTRIAL PROCESS CONTROL: Transducer Channel Isolator for Thermocouples, RTDs, Pressure Bridges, Flow Meters q 4mA TO 20mA LOOP ISOLATION q MOTOR AND SCR CONTROL q GROUND LOOP ELIMINATION q ANALYTICAL MEASUREMENTS q POWER PLANT MONITORING q DATA ACQUISITION/TEST EQUIPMENT ISOLATION q MULTIPLEXED SYSTEMS WITH CHANNEL TO CHANNEL ISOLATION
Isolation Barrier Offset Adjust Offset Adjust -I/P 8 7 3 38 O/P High
DESCRIPTION
The ISO212P signal isolation amplifier is a member of a series of low-cost isolation products from BurrBrown. The low-profile SIL plastic package allows PCB spacings of 0.5" to be achieved, and the small footprint results in efficient use of board space. To provide isolation, the design uses high-efficiency, miniature toroidal transformers in both the signal and power paths. An uncommitted input amplifier and an isolated external bipolar supply ensure the majority of input interfacing or conditioning needs can be met. The ISO212P accepts an input voltage range of 5V for single 15V supply operation or 3.0V for single 10V supply operation.
+I/P
1
37
O/P Low
fB +VSS 1 Out Com 1 -VSS 1 Out
4 6 2 5 34 35 DC/DC Converter 31 32 +VCC Com 2 Clock Out Clock In
International Airport Industrial Park * Mailing Address: PO Box 11400, Tucson, AZ 85734 * Street Address: 6730 S. Tucson Blvd., Tucson, AZ 85706 * Tel: (520) 746-1111 * Twx: 910-952-1111 Internet: http://www.burr-brown.com/ * FAXLine: (800) 548-6133 (US/Canada Only) * Cable: BBRCORP * Telex: 066-6491 * FAX: (520) 889-1510 * Immediate Product Info: (800) 548-6132
(c)
1988 Burr-Brown Corporation
PDS-881G
Printed in U.S.A. December, 1995
SPECIFICATIONS
ELECTRICAL
At TA = +25C and V CC = +15V, unless otherwise noted. ISO212JP PARAMETER ISOLATION Voltage Rated Continuous AC, 50Hz DC 100% Test (AC, 50Hz) Isolation-Mode Rejection(1) CONDITIONS MIN TYP MAX MIN ISO212KP, JP-15 TYP MAX UNITS
750 1060 Partial Discharge 1s : <5pC VISO = Rated Continuous 60Hz 1200
1500 2120 2400
Vrms VDC Vrms
AC DC Barrier Resistance Barrier Capacitance Leakage Current(8) GAIN Initial Error Gain vs Temperature Nonlinearity(3): KP JP-15 INPUT OFFSET VOLTAGE Offset Voltage RTI: KP JP-15 vs Temperature vs Power Supply(4) Adjustment Range INPUT CURRENT Bias Offset INPUT Voltage Range(5) Resistance OUTPUT Output Impedance Voltage Range Ripple Voltage(6) Ouput Compliance FREQUENCY RESPONSE Small Signal Bandwidth Full Signal Bandwidth
VISO = 240Vrms, 60Hz VISO = 240Vrms, 50Hz
115 160 1010 12 1
2 1.6 2 50 0.05
T(9) T T T T
T T T T 0.025 0.05 7.5 7.5/G 10 10/G
dB dB pF Arms Arms % FSR(2) ppm of FSR/C %FSR %FSR mV mV V/C mV/V mV nA nA V k V mVp-p mVrms V kHz Hz kHz
VO = -5V to +5V
1 20 0.04
T T 0.015 0.04
10 10/G 30 30/G 1.5 T 50 4 G=1 5 1012 3 Out Hi to Out Lo Min Load = 1M f = 0 to 100kHz f = 0 to 5kHz Out Hi or Out Lo I/P = 1Vp-p, -3dB G=1 I/P = 10Vp-p, G=1 G = 10 (-3dB) No Load 7.5 5 8 0.4 7.5 1 200 1.8 8 -8 90 5 8 Rated Performance No Load 0 -25 15 11.4 to 16 2.5 T T 3.5 +70 +85 T T T T T T T T T T T T T T T
VCC = 14V to 16V
20
T T
T T
ISOLATED POWER OUTPUTS Voltage Outputs (VSS 1)(7) vs Temperature vs Load Current Output (7) (Both Loaded) (One Loaded) POWER SUPPLIES Rated Voltage Voltage Range(5) Quiescent Current TEMPERATURE RANGE Specification Operating
VDC mV/C mV/mA T T mA mA V V mA C C
T T T T
NOTES: (1) Isolation-mode rejection is the ratio of the change in output voltage to a change in isolation barrier voltage. It is a function of frequency. (2) FSR = Full Scale Range = 10V. (3) Nonlinearity is the peak deviation of the output voltage from the best-fit straight line. It is expressed as the ratio of deviation to FSR. (4) Power Supply Rejection is the change in VOS/Supply Change. (5) At VCC = +10.0V, input voltage range = 3.0V min. (6) Ripple is the residual component of the barrier carrier frequency generated internally. (7) Derated at VCC < +15V. (8) Tested at 2400Vrms, 50Hz limit 16A. (9) Asterisk (T) same as ISO212JP.
(R)
ISO212P
2
PIN CONFIGURATION
Bottom View
ABSOLUTE MAXIMUM RATINGS
Supply Voltage Without Damage ......................................................... 18V Continuous Isolation Voltage Across Barrier: JP ......................... 750Vrms KP, JP-15 ........... 1500Vrms Storage Temperature Range ............................................ -25C to 100C Lead Temperature (soldering, 10s) ................................................ +300C Amplifier Output Short-Circuit Duration ................ Continuous to Common Output Voltage Hi or Lo to Com 2 .................................................. VCC /2
1 +I/P Com 1 2 fB 4 +VSS1 6 Offset Adjust 8 3 -I/P 5 -VSS 1 7 Offset Adjust
PACKAGE/ORDERING INFORMATION
PACKAGE DRAWING NUMBER(1) 326 326 326 TEMPERATURE RANGE -25C to +85C -25C to +85C -25C to +85C
PRODUCT ISO212JP ISO212JP-15 ISO212KP 31 +VCC Com 2 32 Clock Out 34 35 Clock In 37 O/P Low O/P High 38
PACKAGE 38-Pin Plastic SIP 38-Pin Plastic SIP 38-Pin Plastic SIP
NOTE: (1) For detailed drawing and dimension table, please see end of data sheet, or Appendix C of Burr-Brown IC Data Book.
ELECTROSTATIC DISCHARGE SENSITIVITY
This integrated circuit can be damaged by ESD. Burr-Brown recommends that all integrated circuits be handled with appropriate precautions. Failure to observe proper handling and installation procedures can cause damage. ESD damage can range from subtle performance degradation to complete device failure. Precision integrated circuits may be more susceptible to damage because very small parametric changes could cause the device not to meet its published specifications.
TYPICAL PERFORMANCE CURVES
At TA = +25C, VS = 15V, unless otherwise noted.
7 6
VOLTAGE OUT vs SUPPLY VOLTAGE +VCC
SINE RESPONSE (f = 200Hz)
+5
Voltage Out (V)
5 4 3 2
-VOUT VOUT VOUT
+VOUT
Ideal +VOUT
Output Voltage (V)
0
VIN
-VOUT (Absolute)
1 0
Ideal VIN
5 VIN = 5V, G = 1
9 8 7 6 5 4
17 16 15 14 13 12
11 10
0
5 Time (ms)
10
Supply Voltage VCC (V)
The information provided herein is believed to be reliable; however, BURR-BROWN assumes no responsibility for inaccuracies or omissions. BURR-BROWN assumes no responsibility for the use of this information, and all use of such information shall be entirely at the user's own risk. Prices and specifications are subject to change without notice. No patent rights or licenses to any of the circuits described herein are implied or granted to any third party. BURR-BROWN does not authorize or warrant any BURR-BROWN product for use in life support devices and/or systems.
(R)
3
ISO212P
TYPICAL PERFORMANCE CURVES (CONT)
At TA = +25C and VS = 15V, unless otherwise noted.
SINE RESPONSE (f = 2kHz)
STEP RESPONSE (f = 200Hz)
+500
Output Voltage (mV)
+5
0
Output Voltage (V)
VIN = 0.5V, G = 1 0 500 Time (s) 1000
0
-500
-5 V IN = 5V, G = 1 0 5 Time (ms) 10
STEP RESPONSE (f = 2kHz) 85 80 +500
Output Voltage (mV)
IMR vs FREQUENCY
75 70
IMR (dB)
V IN = 0.5V, G = 1 0 500 Time (s) 1000
0
65 60 55
-500
50 45 40 1k 10k 100k 1M 10M 100M
Frequency (Hz)
LINEARITY vs CLOCK-IN RATE 100 90 80
Linearity Error (m%)
GAIN ERROR vs CLOCK-IN RATE 0
-0.5
Gain Error (% FSR)
70 60 50 40 30 20 10 0 30 40 50 60 70 80 90 100 Clock-In Rate (kHz)
-1
-1.5
-2
-2.5 30 40 50 60 70 80 90 100 Clock-In Rate (kHz)
(R)
ISO212P
4
DISCUSSION OF SPECIFICATIONS
The ISO212P is intended for applications where isolation and input signal conditioning are required. Best signal-tonoise performance is obtained when the input amplifier gain setting is such that VOUT has a full scale range of 5V. The bandwidth is typically 1kHz, making the device ideal for use in conjunction with sensors that monitor slowly varying processes. To power external functions or networks, 5mA at 8V typical is available at the isolated port. LINEARITY PERFORMANCE The ISO212P offers linearity performance compatible with 12-bit resolution systems (0.025%). Note that the specification is based on a best-fit straight line. OPTIONAL OFFSET VOLTAGE ADJUSTMENT In many applications, the untrimmed input offset voltage will be adequate. For situations where it is necessary to trim the offset, a potentiometer can be used. See Figure 1 for details. It is important to keep the traces to the offset adjust pins as short as practical, because noise can be injected into the input op amp via this route. INPUT PROTECTION If the ISO212P is used in systems where a transducer or sensor does not derive its power from the isolated power available from the device, then some input protection must be present to prevent damage to the input op amp when the ISO212P is not powered. A resistor of 5k should be included to limit the output impedance of the signal source. Where the op amp is configured for an inverting gain, then RIN of the gain setting network can be used. For non-
inverting configurations, a separate resistor is required. Neglecting this point may also lead to problems when powering on the ISO212P. USING VSS1 TO POWER EXTERNAL CIRCUITRY The DC/DC converter in the ISO212P runs at a switching frequency of 25kHz. Internal rectification and filtering is sufficient for most applications at low frequencies or with no external networks connected. The ripple on VSS1 will typically be 100mVp-p at 25kHz. Loading the supplies will increase the ripple unless extra filtering is added externally; a capacitor of 1F is normally sufficient for most applications, although in some cases 10F may be required. Noise introduced onto VSS1 should be decoupled to prevent degraded performance.
THEORY OF OPERATION
The ISO212P has no galvanic connection between the input and output. The analog input signal referenced to the input common (Com 1) is multiplied by the gain of the input amplifier and accurately reproduced at the output. The output section uses a differential design so either the HI or LO pin may be referenced to the output common (Com 2). This allows simple input signal inversion while maintaining the high impedance input configuration. A simplified diagram of the ISO212P is shown in Figure 2. The design consists of a DC/DC converter, an uncommitted input operational amplifier, a modulator circuit and a demodulator circuit. Magnetic isolation is provided by separate transformers in the power and signal paths. The DC/DC converter provides power and synchronization signals across the isolation barrier to operate the operational amplifier and modulator circuitry. It also has sufficient capacity to power external input signal conditioning net-
Isolation Barrier 3 -I/P 5k VIN 2 Com 1 O/P Low 37 Com 2 32 +V SS 1 -V SS 1 Offset Out Adjust Out 6
(2)
4 fB
35
34
1
+I/P
Clock Clock In Out O/P High 38 VOUT
+V
CC
5 7 100k 8
(1)
31
0.1F 10F Tantalum + 100H Input Ground Plane Output Ground Plane
10F
+
(2)
+
10F
NOTES: (1) Optional voltage offset adjust components. (2) 10F decoupling to be used with external loads connected.
FIGURE 1. Power Supply and Signal Connections Shown for Non-Inverting, Unity Gain Configuration.
(R)
5
ISO212P
works. The uncommitted operational amplifier may be configured for signal buffering or amplification, depending on the application. The modulator converts the input signal to an amplitudemodulated AC signal that is magnetically coupled to the demodulator by a miniature transformer providing the signal-path isolation. The demodulator recovers the input signal from the modulated signal using a synchronous technique to minimize noise and interference. ABOUT THE BARRIER For any isolation product, barrier integrity is of paramount importance in achieving high reliability. The ISO212P uses miniature toroidal transformers designed to give maximum isolation performance when encapsulated with a high-dielectric-strength material. The internal component layout is designed so that circuitry associated with each side of the barrier is positioned at opposite ends of the package. Areas where high electric fields can exist are positioned in the center of the package. The result is that the dielectric strength of the barrier typically exceeds 3kVrms. ISOLATION VOLTAGE RATINGS Because a long term test is impractical in a manufacturing situation, the generally accepted practice is to perform a production test at a high voltage for some shorter time. The relationship between actual test voltage and the continuous derated maximum specification is an important one. Historically, Burr-Brown has chosen a deliberately conservative one: VTEST = (2 x ACrms continuous rating) + 1000V for ten seconds, followed by a test at rated ACrms voltage for one minute. This choice was appropriate for conditions where system transients were not well defined.
Recent improvements in high voltage stress testing have produced a more meaningful test for determining maximum permissible voltage ratings, and Burr-Brown has chosen to apply this new technology in the manufacture and testing of the ISO212P. PARTIAL DISCHARGE When an insulation defect such as a void occurs within an insulation system, the defect will display localized corona or ionization during exposure to high voltage stress. This ionization requires a higher applied voltage to start the discharge and a lower voltage to extinguish it once started. The higher start voltage is known as the inception voltage and the lower voltage is called the extinction voltage. Just as the total insulation system has an inception voltage, so do the individual voids. A voltage will build up across a void until its inception voltage is reached. At this point, the void will ionize, effectively shorting itself out. This action redistributes electrical charge within the dielectric and is known as partial discharge. If the applied voltage gradient across the device continues to rise, another partial discharge cycle begins. The importance of this phenomenon is that if the discharge does not occur, the insulation system retains its integrity. If the discharge begins and is allowed to continue, the action of the ions and electrons within the defect will eventually degrade any organic insulation system in which they occur. The measurement of partial discharge is both useful in rating the devices and in providing quality control of the manufacturing process. The inception voltage of these voids tends to be constant, so that the measurement of total charge being re-distributed within the dielectric is a very good indicator of the size of the voids and their likelihood of becoming an incipient failure.
fB Off Adjust -I/P +I/P Off Adjust
4 7 3 1 8 Signal Modulator
+
-
38 Demodulator 37 31
O/P High
O/P Low +VCC Clock Out Clock In Com 2
+8V +VSS 1 O/P 6 0.47F -VSS 1 O/P 5 0.47F Com 1 2 -8V Rectifier
Power Oscillator 25kHz
50kHz 34 35 32
FIGURE 2. Simplified Diagram of Isolation Amplifier.
(R)
ISO212P
6
The bulk inception voltage, on the other hand, varies with the insulation system and the number of ionization defects. This directly establishes the absolute maximum voltage (transient) that can be applied across the test device before destructive partial discharge can begin. Measuring the bulk extinction voltage provides a lower, more conservative, voltage from which to derive a safe continuous rating. In production, it's acceptable to measure at a level somewhat below the expected inception voltage and then de-rate by a factor related to expectations about the system transients. The isolation amplifier has been extensively evaluated under a combination of high temperatures and high voltage to confirm its performance in this respect. The ISO212P is free of partial discharges at rated voltages. PARTIAL DISCHARGE TESTING IN PRODUCTION Not only does this test method provide far more qualitative information about stress withstand levels than did previous stress tests, but it also provides quantitative measurements from which quality assurance and control measures can be based. Tests similar to this test have been used by some manufacturers such as those of high voltage power distribution equipment for some time, but they employed a simple measurement of RF noise to detect ionization. This method was not quantitative with regard to energy of the discharge and was not sensitive enough for small components such as isolation amplifiers. Now, however, manufacturers of HV test equipment have developed means to measure partial discharge, and VDE, the German standards group, has adopted use of this method for the testing of opto-couplers. To accommodate poorly defined transients, the part under test is exposed to a voltage that is 1.6 times the continuous rated voltage and must display < 5pC partial discharge level in a 100% production test.
the barrier will increase AC leakage and, in conjunction with ground line resistance, may degrade high frequency IMR. VOLTAGE GAIN MODIFICATIONS The uncommitted operational amplifier at the input can be used to provide gain, signal inversion, active filtering or current to voltage conversion. The standard design approach for any op-amp stage can be used, provided that the full scale voltage appearing on fB does not exceed 5V. If the input op-amp is overdriven, ripple at the output will result. To prevent this, the feedback resistor should have a minimum value of 10k. Also, it should be noted that the current required to drive the equivalent impedance of the feedback network is supplied by the internal DC/DC converter and must be taken into account when calculating the loading added to VSS1. Since gain inversion can be incorporated in either the input or output stage of the ISO212P, it is possible to use the input amplifier in a non-inverting configuration and preserve the high impedance this configuration offers. Signal inversion at the output is easily accomplished by connecting O/P High to Com 2 instead of O/P Low. ISOLATED POWER OUTPUT DRIVE CAPABILITY On the input side of the ISO212P, there are two power supplies capable of delivering 5mA at 8V to power external circuitry. When using these supplies with external loads, it is recommended that additional decoupling in the form of 10F tantalum bead capacitors be added to improve the voltage regulation. Loss of linearity will result if additional filtering is not used with an output load. Again, power dissipated in the feedback loop around the input op amp must be subtracted from the available power output at VSS1. If the ISO212P is to be used in multiple applications, care should be taken in the design of the power distribution
INSTALLATION AND OPERATING INSTRUCTIONS
POWER SUPPLY AND SIGNAL CONNECTIONS As with any mixed analog and digital signal component, correct decoupling and signal routing precautions must be used to optimize performance. Figure 1 shows the proper power supply and signal connections. VCC should be bypassed to Com 2 with a 0.1F ceramic capacitor as close to the device as possible. Short leads will minimize lead inductance. A ground plane will also reduce noise problems. If a low impedance ground plane is not used, signal common lines, and either O/P High or O/P Low pin should be tied directly to the ground at the supply and Com 2 returned via a separate trace to the supply ground. To avoid gain and isolation mode (IMR) errors introduced by the external circuit, connect grounds as indicated in Figure 3. Layout practices associated with isolation amplifiers are very important. In particular, the capacitance associated with the barrier, and series resistance in the signal and reference leads, must be minimized. Any capacitance across
CEXT 1 has minimal effect on total IMR. fB - CINT O/P High Load Circuit CEXT 2 and R have a direct effect.
R + CEXT 2 O/P Low Com 2 CEXT 1
-VCC
+VCC
Com 1 Input Common VISO
Power Supply
FIGURE 3. Technique for Connecting Com 1 and Com 2.
(R)
7
ISO212P
network, especially when all ISO212Ps are synchronized. It is best to use a well decoupled distribution point and to take power to individual ISO212Ps from this point in a star arrangement as shown in Figure 4. NOISE Output noise is generated by residual components of the 25kHz carrier that have not been removed from the signal. This noise may be reduced by adding an output low pass filter (see Figure 8). The filter time constants should be set below the carrier frequency. The output from the ISO212P is a switched capacitor and requires a high impedance load to prevent degradation of linearity. Loads of less than 1M will cause an increase in noise at the carrier frequency and will appear as ripple in the output waveform. Since the output signal power is generated from the input side of the barrier, decoupling of the VSS 1 outputs will improve the signal to noise ratio. SYNCHRONIZATION OF THE INTERNAL OSCILLATOR The ISO212P has an internal oscillator and associated timing components, which can be synchronized, incorporated into the design. This alleviates the requirement for an external high-power clock driver. The typical frequency of oscillation is 50kHz. The internal clock will start when power is applied to the ISO212P and Clk In is not connected. Because the frequencies of several ISO212Ps can be marginally different, "beat" frequencies ranging from a few Hz to a few kHz can exist in multiple amplifier applications. The design of the ISO212P accommodates "internal synchronous" noise, but a synchronous beat frequency noise will not be strongly attenuated, especially at very low frequencies if it is introduced via the power, signal, or potential grounding paths. To overcome this problem in systems where several ISO212Ps are used, the design allows synchronization of each oscillator in a system to one frequency. Do this by forcing the timing node on the internal oscillator with an
external driver connected to Clk In. See Figure 5. The driver may be an external component with Series 4000 CMOS characteristics, or one of the ISO212Ps in the system can be used as the master clock for the system. See Figure 6 and 7 for connections in multiple ISO212P installations. CHARGE ISOLATION When more than one ISO212P is used in synchronous mode, the charge which is returned from the timing capacitor (220pF in Figure 5) on each transition of the clock becomes significant. Figure 7 illustrates a method of isolating the "Clk Out" clamp diodes (Figure 5) from this charge. A 22k resistor (recommended maximum to use) together with the 39k internal oscillator timing resistor (Figure 5) forms a potential divider. The ratio of these resistors should be greater than 0.6 which ensures that the input voltage triggers the inverter connected to "Clk In". If using a single resistor, then account must be taken of the paralleled timing resistors. This means that the 22k resistor must be halved to drive two ISO212Ps, or divided by 8 if driving 8 ISO212Ps to insure that the ratio of greater than 0.6 is maintained. The series resistors shown in Figure 7 reduce the high frequency content of the power supply current.
APPLICATIONS
The ISO212P isolation amplifier, together with a few low cost components, can isolate and accurately convert a 4-to20mA input to a 10V output with no external adjustment. Its low height (0.43" (11mm) ) and small footprint (2.5" x 0.33" (57mm x 8mm) ) make it the solution of choice in 0.5" board spacing systems and in all applications where board area savings are critical. The ISO212P operates from a single +15V supply and offers low power consumption and 12-bit accuracy. On the input side, two isolated power supplies capable of supplying 5mA at 8V are available to power external circuitry.
Power In
Track Resistance/Inductance
+VCC
Clock In
ISO212P
ISO212P
ISO212P
39k
220pF
100F 10F 0.1F 0.1F
10F Ground Plane
0.1F
10F
Clock Out
Clamp Diodes
0.1F
Com 2
FIGURE 4. Recommended Decoupling and Power Distribution.
FIGURE 5. Equivalent Circuit, Clock Input/Output. Inverters are CMOS.
(R)
ISO212P
8
ISO212P/Master +V CC Clk Out Clk In Com 2 ISO212P/Slave +V CC Clk Out Clk In Com 2 ISO212P/Slave +V CC Clk Out Clk In Com 2 0V +15V Sync
APPLICATIONS FLEXIBILITY In Figure 8, the ISO212P's +Vss 1 isolated supply powers a REF200 to provide an accurate 100A current source. This current is opposed by an equal but opposite current through the 75k feedback resistor to establish an offset of -7.5V at Iin = 0mA. With Iin = 4-to-20mA, the output is -5 to +5V. The ratio of the 75k and 3.12k resistors assures the correct gain. The polarity of the output can be reversed by simply reversing the O/P HI and O/P LO pins. This could be used in the Figure 8 circuit to change the -5V to +5V output to a +5V to -5V output range. The primary function of the output circuitry is to add gain to produce a 10V output and to reduce output impedance. The addition of a few resistors and capacitors provides a low pass filter with a cut-off frequency equal to the full signal bandwidth of the ISO212P, typically 200Hz. The filter response is flat to 1dB and rolls off from cut off at -12dB per octave. The accuracy of the REF200 and external resistors eliminates the need for expensive trim pots and adjustments. The errors introduced by the external circuitry only add about 10% of the ISO212P's specified gain and offset voltage error.
FIGURE 6. Oscillator Connections for Synchronous Operation in Multiple ISO212P Installations.
22k Clk Out Master Slave Clk In Slave
22k Clk In Slave
22k Clk In Slave
22k Clk In Slave Clk In Slave N Slave 4
22k
RS Clk Out Slave 1 Master Clk In Slave 2 Clk In Slave 3 Clk In
FIGURE 7. Isolating the Clk Out Node.
+VSS 1 +15V 10F 0.1F 2 1 +VSS 1 8 100A 1 75k 0.02F 3.12k 22k
REF 200
6.8nF (10%)
6 + 31 37 (O/P Low) 38 (O/P High) 100k (5%) 4 ISO212P 4mA to 20mA -5V to +5V 100k (5%) 6.8nF (10%) 3
+
+15V 0.1F 4mA to 20mA -10V to +10V 6
4-20mA
25
3
-
32
OPA27 2-
0.1F
NOTE: All resistors are 0.1% unless otherwise stated.
-15V 22k
FIGURE 8. Isolated 4-20mA Current Receiver with Output Filter.
(R)
9
ISO212P
+VISO
+15V
REF03
+2.5V 3 - 31 38 ISO212P
OPA1013
0.1F
1k
1k 1 99k 4
VOUT 37 32 5
+ 6 2
+VISO
1k
1k(1) -2.5V 100
OPA1013
10F 10F +VISO -VISO
NOTE: (1) e.g., strain gauge, pressure transducer, RTD, gas detection and analysis.
-VISO
FIGURE 9. Instrument Bridge Isolation Amplifier.
100k 4 0.1F 100k 3 +15V
0.1F
- 31 38 VOUT 37 + 5 6 2 32 ISO212P
250k 1 +VISO Siemens BPW21
OPA128J
10F 10F
-VISO
+VISO -VISO
FIGURE 10. Photodiode Isolation Amplifier.
-VISO 8k +VISO 1
+15V
OPA177 4k 100 99k 1k 1M -VISO
ISO212JP 4 3
VOUT
T.C.
-VISO
FIGURE 11. Thermocouple Amplifier with Ground Loop Elimination, Cold Junction Compensation and Down-Scale Burn-Out.
(R)
ISO212P
10
+500VDC 1k
100k ISO212P 4 3 -
VD 1
+15V + 2 0.1F 31 37 38 32 100k 100k 3 2 OPA27 6.8nF +15V 6 -10V to +10V
V D = 50mV (FS) DC Motor
6.8nF
or 90k -15V 22k 22k
120Vrms 100A
4 3-Phase Y-Connected Power Transformer 10k 200k 4.7V 4.7V 200k 1 + 2 3 -
0.1F
FIGURE 12. Isolated Current Monitoring Applications.
+VSS1 8 4 3 REF200 5 1 6 2 200A -VSS1 7
100A
7.87k 4 3 150 ISO212P 1
+15V
0.1F
- 31 38 1 to 5V
37 + 5 6 2 32
PT100 -200C to 850C 10F
10F +VSS1-VSS1
FIGURE 13. Isolated Temperature Sensing and Amplification.
(R)
11
ISO212P


▲Up To Search▲   

 
Price & Availability of ISO212JP

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X